GE PNSF39Z01 Bread Maker User Manual


 
20
About water softener system.
Service: Regeneration and Heavy Duty Backwash
NOTE:
Each of the following functions has a factory set default value. The defaults are: Regeneration
start time
–2:00AM
; Maximum days between regenerations
–0
(display shows
dY–
); Heavy duty
backwash
–OFF
. The defaults are suitable for most installations. However, depending on water
supply quality, household peak water use hours, etc., adjustment is available to meet specific needs.
To make a change, read and do the following.
Regeneration (Start) Time:
At the 2:00 AM regeneration start time, the water
softening system begins
regeneration at that time, ending at about 4:00 AM. This is a good time in most households because
water is not in use (see
Automatic Hard Water Bypass During Regeneration
section). If a different time
would be better for
your needs, do steps 1, 2, 3, 5, 7, 8 and 9 below to change the starting hour.
Maximum Days Between Regeneration:
The default setting (dy-) allows the timer to control
regeneration frequency based on water usage readings from the water meter. It provides the
most economical operation. You can set a maximum time (in days) between regenerations.
For example, no more than three days will pass without a regeneration occurring if you set
dY 3
in the display. A 1 to 7 day setting is available. To make a change from the default setting,
do steps
1, 2, 3, 5, 7, 8 and 9
below.
Heavy Duty Backwash:
When set to
ON
, the backwash cycle of regeneration will be 10 minutes long
instead of the normal seven minute length. This is beneficial on some water supplies high in iron
or sediment content. To conserve water, on clean supplies, be sure the default setting
OFF
shows.
To change this setting, do steps
1, 2, 3, 5, 7, 8 and 9 below.
Auto Regeneration When Capacity is Low:
The softener will regenerate at the regeneration time only.
Although the control has a look-forward feature which anticipates normal demand, an unusually
high usage may result in a loss of softening capacity. Turning the feature
ON
will cause the softener to
go into a regeneration cycle when 97% of the softening capacity has been used. To change settings,
do steps 1, 3, 5, 7, 8 and 9.
Beginning from the present time display, press and hold in the
SET
button until
begins to flash.
Press the
UP
or
DOWN
button to display the desired start time. The
UP
button moves the time
ahead; the
DOWN
button moves the time backward.
Press the
SET
button again, and flashes.
To set a maximum time (in days) between regenerations, press the
UP
or
DOWN
button.
Press the
SET
button to display .
Use the
UP
button to change the display to
ON
to increase the backwash time, if desired.
Press the
SET
button and alternately flashes.
Use the
UP
button to turn
Auto Regeneration
cycle to
ON
.
Press the
SET
button a final time to return to present time of day.