GE Monogram ZIBS240 Refrigerator User Manual


 
14
Questions?
Use this
problem
solver!
The Problem Solver
Bar Refrigerator with Icemaker
PROBLEM POSSIBLE CAUSE
APPLIANCE Appliance may be in defrost cycle when compressor motor does not
DOES NOT OPERATE operate for about 30 minutes.
Appliance is so quiet that most of the time you will hear low or no
operating noise.
Controls are set to OFF. Press ON/OFF button on control panel
for a minimum of 3 seconds.
If interior light is not on, appliance may not be plugged in
at wall outlet. Push the plug completely into the wall outlet.
The fuse is blown/circuit breaker is tripped. Replace fuse or reset
the breaker.
The appliance is in showroom mode. Unplug it and plug it back in.
VIBRATION OR Adjust the leveling legs as shown in the Installation Instructions.
RATTLING (Slight
vibration is normal.)
COMPRESSOR Normal when appliance is first plugged in. Wait 24 hours for the
MOTOR OPERATES appliance to completely cool down.
FOR LONG PERIODS
Often occurs when large amounts of food are placed in appliance.
OR CYCLES ON AND
This is normal.
OFF FREQUENTLY
Door left open or package holding door open.
Hot weather or frequent door openings. This is normal.
Temperature control set at the coldest setting.
See Temperature Control.
FRESH FOOD Temperature control not set cold enough.
COMPARTMENT See Temperature Control. Allow 12 to 24 hours for temperature
TOO WARM to change.
Warm weather or frequent door openings.
Door left open for long time.
Package may be holding door open.
Thermistor may be blocked, which can affect the overall temperature.
The thermistor is located on the right hand side just above the
top shelf.
FROST OR ICE Too frequent or too long door openings.
CRYSTALS ON
Thermistor may be blocked, which can affect the overall temperature.
REAR WALL
The thermistor is located on the right hand side just above the
top shelf.
AUTOMATIC Icemaker power switch is in the O (off) position.
ICEMAKER
Water supply turned off or not connected. See Installation Instructions.
DOES NOT WORK
Freezer compartment too warm. Allow 24 hours for the appliance
to completely cool down.
Piled up cubes in storage bin cause icemaker to shut off.
Level cubes in bin.
Ice cubes stuck in icemaker (green power light on the icemaker is
blinking). Turn off the icemaker, remove cubes and turn the
icemaker back on.