Greenheck Fan PN 471755 Ventilation Hood User Manual


 
Sidewall Propeller Fans • Exhaust, Supply and Filtered Supply
®
3
Fan
Size
Damper
Size
Square
Recommended Wall Opening (W.O.)
Square
M
Minimum
Filtered Supply Wall Housing Only
Figures 1
and 2
Figure 3 Figure 4 A B C Filter Quantity & Size
8 10 (254) 14¼ (362) 10½ (267) - 6 (152) - - - -
10 12 (305) 16¼ (413) 12½ (318) - 6 (152) - - - -
12 14 (356) 19¼ (489) 14½ (368) - 7 (178) - - - -
14 16 (406) 21¼ (540) 16½ (419) - 8 (203) - - - -
16 18 (457) 23¼ (591) 18½ (470) - 9 (229) - - - -
18 20 (508) 25¼ (641) 20½ (521) - 10 (254) - - - -
20 22 (559) 27¼ (692) 22½ (572) - 12 (305) - - - -
24 26 (660) 33¾ (857) 26½ (673) 33
3
4 (857) 13 (330) 32
1
4 (819) 63 (1600) 24 (610) 4 23
1
4 x 16
1
4 (591 x 413)
30 32 (813) 39¾ (1010) 32½ (826) 39
3
4 (1010) 13 (330) 38
1
4 (972) 65 (1651) 26 (660) 4 24
5
8 x 19
1
4 (625 x 489)
36 38 (965) 45¾ (1162) 38½ (978) 45
3
4 (1162) 14 (356) 44
1
4 (1124) 67
1
4 (1708) 28¼ (718) 6 23
1
4 x 22
1
8 (591 x 562)
42 44 (1118) 51¾ (1314) 44½ (1130) 51
3
4 (1314) 15 (381) 50
1
8 (1273) 72
7
8 (1851) 34 (864) 6 24
1
8 x 25
1
8 (613 x 638)
48 50 (1270) 57¾ (1467) 50½ (1283) 57
3
4 (1467) 16 (406) 56
1
8 (1426) 72
7
8 (1851) 34 (864) 12 23
1
4 x 18
3
4 (591 x 476)
54 56 (1422) 63¾ (1619) 56½ (1435) 63
3
4 (1619) 17 (432) 62
3
8 (1584) 79
11
16 (2024) 40
11
16 (1033) 12 23
1
4 x 20
3
4 (591 x 527)
60 62 (1575) 69¾ (1772) 62½ (1588) - 19 (483) - - - -
72 74 (1880) 84¾ (2153) 74½ (1892) - 19 (483) - - - -
All dimensions given in inches (millimeters). Filters are 2 inch (51 mm) nominal thickness. Above filter sizes are actual dimensions.
M
W.O.
W.O.
W.O.
M
W.O.
W.O.
W.O.
Figure 1 - Wall Housing Installation Figure 2 - Wall Collar Installation
Figure 3 - Direct to Wall Installation Figure 4 - Filtered Supply Wall Housing Installation
M
W.O.
W.O.
W.O.
Filters
Wall
Housing
Filter
Section
INTERIOR
Wall
EXTERIOR
Optional 90º
Weatherhood
Filters
Airflow
Optional
Damper
Wall
A
C
B
24 in. 15 in.
Pre-Installation Checks
Check chart below for correct wall opening
dimensions.
Check motor voltage and amperage rating for
compatibility with electrical supply. Supply wiring
must be properly fused and conform to local and
national codes.
Motor load amperage must be checked and
compared to nameplate rating to avoid serious
damage to motor when speed is increased.
Wall Opening Requirements
Wall opening size and propeller-to-damper distance
are two important dimensions for fan installation.
Fans mounted to the wall require a different wall
opening (W.O.) size than those mounted in collars or
wall housings. Propeller-to-damper distance (M) is
important to reduce turbulence and damper flutter
which may lead to premature damper failure.
Figure 1 and 2 show the wall opening (W.O.) required
for installations with either a wall housing or collar.
Figure 3 shows the recommended wall opening
(W.O.) and the minimum distance (M) suggested
between the fan and damper for direct to wall
installations.
Figure 4 shows the dimensions and wall opening
(W.O.) required for installations with a filtered supply
wall housing.