9
Electrical Data
Model
Power
Supply
Compressor
Air Defrost/
Beacon II
™
Electric Defrost - Low
Amps
Electric Defrost - High
Amps
Model RLA LRA MCA MOPD
Defrost
Heater
Amps*
Evap.
Fan
Amps MCA MOPD
Defrost
Heater
Amps*
Evap.
Fan
Amps MCA MOPD
SWN0311L6G 230/1/60 2DF3F16KE 22.9 125.0 28.7 50 20 (1) 6 34.7 50 40 (1) 12 50.0 60
SWN0311L6C 208-230/3/60 2DF3F16KE 14.4 102.0 20.0 30 20 (1) 6 25.0 35 40 (1) 12 50.0 50
SWN0311L6D 460/3/60 2DF3F16KE 7.1 52.0 15.0 15 10 (1) 3 15.0 15 20 (1) 6 25.0 25
SWN0400L6C 208-230/3/60 2DL3F20KE 23.6 161.0 29.5 50 20 (1) 6 35.5 50 40 (1) 12 50.0 60
SWN0400L6D 460/3/60 2DL3F20KE 9.2 60.0 15.0 20 10 (1) 3 15.0 20 20 (1) 6 25.0 25
SWN0599L6C 208-230/3/60 2DA3F23KE 25.8 161.0 32.3 50 20 (1) 6 38.3 60 40 (1) 12 50.0 70
SWN0599L6D 460/3/60 2DA3F23KE 9.2 60.0 15.0 20 10 (1) 3 15.0 20 20 (1) 6 25.0 25
SWN0600L6C 208-230/3/60 2DB3F25KE 25.3 161.0 31.7 50 20 (1) 6 37.7 60 40 (1) 12 50.0 60
SWN0600L6D 460/3/60 2DB3F25KE 11.9 80.0 15.0 25 10 (1) 3 20.0 25 20 (1) 6 25.0 30
SWN0601L6C 208-230/3/60 3DA3F28KE 24.0 150.0 30.1 50 20 (1) 6 36.1 60 40 (1) 12 50.0 60
SWN0601L6D 460/3/60 3DA3F28KE 10.8 77.0 15.0 20 10 (1) 3 20.0 25 20 (1) 6 25.0 30
SWN0750L6C 208-230/3/60 3DB3F33KE 27.6 161.0 34.5 60 40 (1) 12 50.0 70 70 (2) 16 87.5 90
SWN0750L6D 460/3/60 3DB3F33KE 14.1 83.0 20.0 30 20 (1) 6 25.0 35 40 (1) 12 50.0 50
SWN0900L6C 208-230/3/60 3DF3F40KE 33.2 215.0 41.5 70 40 (1) 12 53.5 80 70 (2) 16 87.5 90
SWN0900L6D 460/3/60 3DF3F40KE 15.0 106.0 20.0 30 20 (1) 6 25.0 35 40 (1) 12 50.0 50
SWN1000L6C 208-230/3/60 SDS3F46KE 37.2 215.0 46.5 80 40 (1) 12 58.5 90 70 (2) 16 87.5 90
SWN1000L6D 460/3/60 SDS3F46KE 16.7 106.0 20.8 35 20 (1) 6 26.8 40 40 (1) 12 50.0 50
SWN1500L6C 208-230/3/60 4DL3F63KE 47.2 278.0 59.0 100 70 (2) 16 87.5 110 96 (2) 25 120.0 125
SWN1500L6D 460/3/60 4DL3F63KE 23.6 139.0 29.5 50 40 (1) 12 50.0 60 70 (2) 16 87.5 90
SWN2200L6C 208-230/3/60 4DT3F76KE 59.2 374.0 74.0 125 70 (2) 16 90.0 125 96 (2) 25 120.0 150
SWN2200L6D 460/3/60 4DT3F76KE 29.6 187.0 37.0 60 40 (1) 12 50.0 70 70 (2) 16 87.5 90
SWN Model - Low Temperature
*Number of defrost heater contactors in parentheses
RLA - Rated Load Amps MCA - Minimum Circuit Ampacity
LRA - Locked Rotor Amps MOPD - Maximum Overcurrent Protection Device
For additional capacity sizes and options, please contact the factory at 800-321-1881