Henny Penny 592 Fryer User Manual


 
Model 590/592
DO NOT PULL THE RING ON THE SAFETY
RELIEF VALVE. HOT STEAM WILL BE
RELEASED AND SEVERE BURNS WILL RESULT.
1. At the end of each day’s usage of the fryer, the deadweight
valve must be cleaned. The fryer must be OFF and pressure
released. Open the lid and then remove the deadweight
valve cap and deadweight.
Failure to clean the deadweight assembly daily could
result in the fryer building too much pressure. Severe
injuries and burns could result.
2. Wipe both the cap and weight with a soft cloth. Make
certain to thoroughly clean inside cap, the weight seat, and
around deadweight ori ce.
3. Dry the parts and replace immediately to prevent damage
or loss.
The safety relief valve should be cleaned once a year.
DO NOT ATTEMPT TO REMOVE SAFETY VALVE
WHILE FRYER IS OPERATING, OR SEVERE
BURNS OR OTHER INJURIES WILL RESULT.
1. Remove pressure gauge.
1103 2-15
2-16. DEADWEIGHT VALVE
(Continued)
2-17. REMOVAL & CLEANING
OF SAFETY RELIEF
VALVE
ORIFICE CAP DEADWEIGHT
SAFETY RELIEF VALVE