Model CW-216/CW-114
4-1. TROUBLESHOOTING GUIDE
Product not
• Doors are not kept closed • Keep doors closed when
holding possible
temperature
• Product held too long • Only hold product for
recommended times
• Water temperature too low • Turn to higher setting
• Radiant heat too low • Turn to higher setting
• Light bulbs out • Replace as required, per
Light Bulbs and Glass Panels
Section
Doors are
• Doors left open too much • Keep doors closed when
fogging allowing doors to cool and possible
cause condensation
• Radiant heat not high enough • Turn to higher setting
• Water temperature too high • See recommended settings
and temperatures
Water will
• Water supply has been shut- • Check the water supply
not fill off or disconnected
Lights will
• Defective fuse • Replace 15 amp fuse
not turn on
Not all lights
• Faulty light bulbs • Replace with recommended
on bulb, per Light Bulbs and Glass
Panels Section
Water will not
• Bun pans are not over water • Place perforated bun pans
reach desired over water
temperature
PROBLEM CAUSE CORRECTION
More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com,
or 800-417-8405 or 937-456-8405.
SECTION 4. TROUBLESHOOTING
4-1 203