Henny Penny EEE-143 Fryer User Manual


 
Model EEE-141,142, 143, 144
3-19. INFO BUTTON STATS Actual Oil Temperature
1. Press and the actual oil temperature shows in the
display, for each vat.
Set-point Temperature
2. Press twice and SP shows in the display, along with
the set-point (preset) temperature of each vat.
Recovery Information for each Vat
1. Press 3 times and REC shows in the left display and
the recovery time that oil temperature went from 250°F
(121°C) to 300°F (149°C) shows in the right display. For
example, means it took 5 minutes and
30 seconds for the oil temperature to recover to 300°F
(149°C) from 250°F (121°C).
If no buttons are pressed within 5 seconds in any of stats
modes, the controls revert back to normal operation.
Cook Cycles Remaining before Filtering
1. Press and release either button and the left display
shows “COOKS REMAINING” and the right display shows
the number of cook cycles before the next auto filter. For
example,
means after 3 more cook cycles on the left vat, the controls
asks the operator if they are ready to filter or not. But, 6 more
cook cycles remain on the right vat.
Time and Date
2. Press either twice and ‘FILTERED” shows in the
diplays, along with the time-of-day and date of the last filter.
REC 5:30
3-20. FILTER BUTTON STATS
3-25 309
REMA INING
3 6