Henny Penny PFE-592 Fryer User Manual


 
Model PFE- 590/592
3-13. PREVENTIVE Cleaning Safety Relief Valve-Annually
MAINTENANCE
Continued)
DO NOT ATTEMPT TO REMOVE SAFETY VALVE
WHILE FRYER IS OPERATING, OR SEVERE BURNS
OR OTHER INJURIES WILL RESULT.
DO NOT DISASSEMBLE OR MODIFY THIS SAFETY
VALVE. TAMPERING WITH THIS VALVE COULD
CAUSE SERIOUS INJURIES AND WILL VOID
AGENCY APPROVALS AND APPLIANCE
WARRANTY.
1. Use a wrench to remove pressure gauge.
2. Use a wrench to loosen the valve from the pipe tee, turn
counterclockwise to remove.
3. Clean the inside of the pipe tee with hot water.
Turn the safety relief valve towards the rear of the fryer when
reinstalling the relief valve.
4. Immerse the safety relief valve in a soapy water solution for 24
hours. Use a 1:1 dilution rate. The valve cannot be disas-
sembled. It is factory preset to open at 14-1/2 pounds of
pressure. If it does not open or close, it must be replaced.
703 3-18
SAFETY VALVE