Model PFE- 590/592
Power switch on but fryer
completely inoperative
Pressure not exhausting at
end of Cook Cycle
Operating pressure too high
4-1. TROUBLE SHOOTING GUIDE
Problem Cause Correction
Open circuit
Solenoid or exhaust line clogged
Deadweight clogged
Fryer plugged in
Check breaker or fuse at wall
Turn off and allow fryer to cool to
release the pressure in frypot; have
all lines, solenoid and exhaust tank
cleaned
Turn off and allow fryer to cool to
release the pressure in frypot; clean
deadweight; see Preventive Mainte-
nance Section
DO NOT OPERATE UNIT IF PRESSURE GAUGE SHOWS HIGH PRESSURE CONDITIONS.
SEVERE INJURIES AND BURNS WILL RESULT. IMMEDIATELY PLACE THE POWER/
PUMP SWITCH IN THE OFF POSITION, WHICH RELEASES THE PRESSURE BY ALLOW-
ING THE UNIT TO COOL. DO NOT RESUME USE OF UNIT UNTIL CAUSE OF HIGH
PRESSURE HAS BEEN FOUND AND CORRECTED.
Pressure does not build
Shortening not heating
Foaming or boiling over
Shortening not draining
Filter motor won’t run
Not enough product in frypot
Metal shipping spacer not
removed from deadweight assy.
Pressure not programmed
Lid gasket leaking
Drain valve open
High temperature limit tripped
See Boil-Over chart on fryer
and beginning of Operation
Section in this manual
Drain valve clogged
Motor overheated
Place full capacity product in frypot
when using fresh shortening.
Remove shipping spacer; see
Unpacking Instructions Section
Check programming
Reverse or replace lid gasket
Close drain valve.
Reset high temperature limit; see
Operating Components Section
Follow Boil-Over procedures from
chart
Push cleaning rod through open
drain valve
Reset motor; see Filter Pump Motor
Protector-Manual Reset Section
More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com,
or 1-800-417-8405 or 1-937-456-8405.
4-1 703
SECTION 4. TROUBLESHOOTING