5
NOTES:
* STUB-UP AREA
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
z ENDS ADD APPROXIMATELY 1 INCH TO CASE HEIGHT
z WIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT
z A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND A WALL
z SUCTION LINE (ALL LENGTHS) 1/2"
z LIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"
z AVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20", 22" & 23 1/2"
SOLID SHELVES 18", 20", 22", 24" & 27"
(TOP SHELF MUST BE 24" OR SHORTER WHEN USING 27" SHELVES.
RECOMMENDED CONFIGURATION IS 1 - 24" SHELF AND 4 - 27" SHELVES BELOW
TOP SHELF)
7 1/2 in
[19.1 cm]
1/2 BUMPER OPTION
41 7/16 in [105.2 cm]
6 13/16 in [17.2 cm]*
42 11/16 in [108.4 cm]
COIL
PLENUM
30 7/8 in [78.4 cm]
5 1/8 in
[13.1 cm]
16 1/16 in
[40.9 cm]
8 1/2 in
[21.6 cm]
31 9/16 in [80.2 cm]
39 1/4 in [99.7 cm]
85 1/16 in
[216.0 cm]
87 1/16 in
[221.1 cm]
63 in
[160.1 cm]
66 3/8 in
[168.6 cm]
(Door Height)
68 in
[172.7 cm]
(Frame Height)
C
L
34 11/16 in
[88.1 cm]
31 9/16 in
[80.2 cm]
10 in
[25.4 cm]
JUNCTION BOX
(STANDARD)
8 in [20.3 cm]
WIRING-TO-TOP
(OPTIONAL)
35 1/8 in
[89.2 cm]
**
1 1/2" PVC DRAIN
CONNECTION
28 5/8 in
[72.7 cm]
33 9/16 in
[85.3 cm]
39 1/4 in
[99.7 cm]
REFRIGERATION
1 1/2 in
[3.8 cm]
{END}
8 11/16 in [22.1 cm]
FRONT OF CASE
4 in [10.2 cm]
PIPING-TO-TOP
(OPTIONAL)
12 3/4 in [32.4 cm]
3 3/8 in [8.6 cm]
REAR REFRIGERATION
(13 15/16" off of floor)
42 11/16 in
[108.4 cm]
60 in [152.4 cm] {2 Door}
90 in [228.6 cm] {3 Door}
120 in [304.8 cm] {4 Door}
150 in [381.0 cm] {5 Door}
180 in [457.2 cm] {6 Door}
96 in [243.8 cm] {8' case}
144 in [365.8 cm] {12' case}
ELECTRICAL
16 1/16 in [40.8 cm]
18 9/16 in [47.1 cm]
MODEL
ORBH
Amp plate &
Serial Plate
location