Hill Phoenix ORBH Refrigerator User Manual


 
16
ELECTRICAL HOOKUP
For case-to-case wiring, run “greenfield”,
or other conduit, between junction boxes.
When connecting to the junction box on the
bottom left side of the case, field wiring should
exit the junction box from the right hand side,
furthest away from case wiring, increasing room
inside for wire connecting.
Electrical hookups are made to a
junction box located at the bottom left
hand front of the case. At the owners
option the case made be wired to a junction
box located on the top left rear of the case.
DEFROST HEATERS, 208/240 VOLTS L1
L2
RED
BLUE
EVAPORATOR FANS, 120 VOLT
ANTI-CONDENSATE HEATERS, 120 VOLT
WIRE NUMBERCOMPONENT COLOR CODING
BLACK
TEMPERATURE CONTROL, 120 VOLT
LIGHTS, 120 VOLT
DEFROST TERMINATION CONTROL, 120 VOLT
WHITE
3
4
11
12
13
14
19
20
21
WHITE
BLACK
WHITE
BLACK
YELLOW
YELLOW
PURPLE
ORANGE23
WIRING NUMBERS AND COLORS
EQUIPMENT GROUNDING CONDUCTOR GREEN
-
BLACK
WHITE
DOOR & FRAME ANTI-COND. HEATERS, 120 VOLT 15
16
WIRING-TO-TOP
CONTINUOUS
RACEWAY
JUNCTION BOX
COVER
JUNCTION BOX
CANOPY
WIRING-TO-JUNCTION BOX
JUNCTION
BOX COVER
JUNCTION
BOX
C
L
34 11/16 in
[88.1 cm]
(STANDARD)
31 9/16 in
[80.2 cm]
(STANDARD)
10 in
[25.4 cm]
JUNCTION BOX
(STANDARD)
8 in [20.3 cm]
WIRING-TO-TOP
(OPTIONAL)
ELECTRICAL
35 1/8 in
[89.2 cm]
(STANDARD)
**
39 1/4 in
[99.7 cm]
(STANDARD)
REFRIGERATION
1 1/2 in
[3.8 cm]
{END}
FRONT OF CASE
NOTES:
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
z WIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT
42 11/16 in
[108.4 cm]
(STANDARD)
31 7/8 in
[81.0 cm]
(NARROW)
24 3/16 in
[61.4 cm]
(NARROW)
27 5/16 in
[69.4 cm]
(NARROW)
35 3/8 in
[89.8 cm]
(NARROW)
27 9/16 in
[70.0 cm]
(NARROW)
**
60 in [152.4 cm] {2 Door}
90 in [228.6 cm] {3 Door}
120 in [304.8 cm] {4 Door}
150 in [381.0 cm] {5 Door}
180 in [457.2 cm] {6 Door}
96 in [243.8 cm] {8' case}
144 in [365.8 cm] {12' case}
16 1/16 in [40.8 cm]
18 9/16 in [47.1 cm]
MODEL