USING THE FILTER SYSTEM
Filter system parts must be in their proper positions while the system is in use . . .
Crumb Basket hangs on left Tank Handle (Fig. 4) to catch crumbs during draining.
Filter must be flat on tank bottom and Filter Orifice must be placed over the tank hole (Fig. 4).
Elbow must be threaded into Tank Fitting (Fig. 4).
Lid must be in place over tank. Drain Opening is over Crumb Basket. Elbow extends above
Suction Opening.
Drawer is closed so Suction Connector on Elbow is connected to the Suction Port.
NOTE: Make sure the two O-rings are always in place inside the Suction Port.
Fig. 4
PL-41522-1
LEFT TANK HANDLE CRUMB BASKET TANK FILTER
FILTER ORIFICE UNDERNEATH
SUCTION CONNECTOR
ELBOW
TANK FITTING
LID
SUCTION OPENING
DRAIN OPENING