Hobart CG10FI Oven User Manual


 
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Page 2 of 2 F-40269 – CG10FI Gas Full Size Combi Oven
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
CG10FI GAS
FULL SIZE COMBI OVEN
F-40269 (REV. 06/11) LITHO IN U.S.A. (H-01)
SPECIFICATIONS:
General: Hobart Combi Oven, gas steam generator, 10 level full
size combi.
Construction: All stainless steel interior and exterior. Top, rear,
sides, and bottom are fully insulated. All welded stainless steel
cooking compartment. Stainless steel oven door features a large
curved outer glass with enhanced insulation for a cool to touch
exterior, with full length hinged oating inner glass panel. A full
perimeter door gasket with drip tray inside door and oven frame.
Door opens right to left and swings a full 180 degrees. Standard
with rack guides and (5) wire racks. Built in wash arm for automatic
cleaning with auto dosing pump, 4-speed auto reversing fan,
(3) halogen ashing door lights, core probe, dual point door latch
connection for a full perimeter sealed connection. Standard with
1.6" feet for stand connection.
Controls: Simple, user friendly digital controls on the right with
large, low voltage LCD display - for easy cleaning and operating
pleasure. Manual operation or programmable up to 100 recipes with
10 cooking phases each. Includes Bluetooth
®
communication and
recipe software for PC.
Operation: Hobart’s gas pressureless steam generator and open
burner in the cooking cavity uses optimized cooking functions
and engineering technology for maximum production with minimal
energy and water consumption.
Electrical: 120/60/1 (cord and plug by others).
Gas: 60,000 BTU’s,
3
4" gas connection NPT.
Water: A suitable Hobart Water Treatment System is the recom-
mended minimum to meet the water quality spec.
3
4" NSHT cold
water, 30-60 psi and 1" NPT drain connection.
Capacity: Capable of holding: (20) 12" x 20" x 2
1
2" steam table
pans or (10) 18" x 26" x 1" sheet pans or (20) 13" x 18" x 1" half size
sheet pans.
User Responsibility: The product must be installed, cleaned and
maintained as described in the Manual furnished with the product.
Water Quality Specication for Warranty Purposes
The fact that a water supply is potable is no guarantee that it is
suitable for steam generation. All steam equipment is subject to
contamination and failure due to chemical and mineral content
found in water. A suitable Hobart Water Treatment System and
regular lter replacements coupled with routine deliming is the
recommended minimum. Damage as a result of poor water quality
or lack of required owner/operator maintenance is the responsibility
of the owner/operator.
DETAILS AND DIMENSIONS:
Your water supply must be within these general guidelines:
DYNAMIC WATER PRESSURE 30-60 psig
HARDNESS * less than 3 grains
SILICA less than 13 ppm
TOTAL CHLORIDE less than 30 ppm
Ph RANGE 7-8
CHLORINE & CHLORAMINE 0 ppm
ALKALINITY less than 20 ppm
TDS less than 60 ppm
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount
of chlorination and dissolved gasses. Water supplies vary from
state to state and from locations within a state. Therefore it is
necessary that the local water treatment specialist be consulted
before the installation of any steam generating equipment.
Note:
• Installationofbackowpreventers,vacuumbreakersandother
specic code requirements is the responsibility of the owner
and installer in compliance with local codes.
• Plasticdrainsarenotrecommendedduetoinherentlimited
temperatures of the plastic. The installer may be required to
provide means to reduce water drain temperature to be that of
the condensate temperature of 140°F or less.
Model Width Depth Height Weight
CG10FI 35.4" 45.0" 36.8" 437 lbs.
Model Electrical Gas
*
CG10FI 120/60/1 60,000 BTU
NOTES:
Amperage values in the table are nominal. Tolerance is +5/-10%.
* Natural gas. Values rounded to 1,000. Maximum usage shown.
LEGEND:
1. GAS
2. DRAIN
3. ALTERNATE DRAIN
4. WATER SUPPLY
5. ELECTRIC
Gas Presure: A regulator sized for this unit is included. Natural gas
5" W.C., propane gas 10" W.C. supply pressure.
Clearance: Left 1", Back 2", Right 2" required, 18" recommended
for service access.