Hobart EFO40 Fryer User Manual


 
– 9 –
LIGHTING INSTRUCTIONS (Fig. 3)
1. Turn thermostat knob OFF.
2. Depress gas valve extension arm and turn to OFF. Wait 5 minutes for unburned gas to vent.
3. Depress gas valve extension arm and turn to PILOT.
4. While still depressing arm, light pilot with a lit taper. Continue with Steps 2, 3, and 4 until pilot
remains lit when extension arm is released.
5. Turn gas valve extension arm ON.
6. Repeat above procedures if gas supply is interrupted.
Fig. 3
OVER TEMPERATURE DEVICE
If the shortening becomes overheated, a high temperature shutoff device will turn the gas valve off and
extinguish the pilot. DO NOT relight the pilot until the shortening temperature has lowered to at least
300°F (149°C). If the situation persists, contact your local Hobart service office.
TURNING THE FRYER ON
CAUTION: Before turning the burners on, the fry tank must be filled with liquid shortening. If
this is not done, the tank walls can be damaged. Warpage can cause leaks.
Set the thermostat to the desired temperature. When the set temperature is reached, the gas control
shuts off gas flow to the burners while the pilot remains lit. If cold food is introduced and the oil
temperature falls, the burners will come on to maintain the temperature.
PL-40676-1
Gas Valve
Extension Arm
Thermostat
Knob