Hobart FT900SBD Dishwasher User Manual


 
19
COMMUNICATIONS SETUP MENU TABLE 2
Parameter Description Possible Default Security
Name Values Value Required
NAFEM DP Baud Adjusts the baud rate of communication between the 9600
dishwasher and a NAFEM Data Protocol (NDP) Gateway to 9600 M
(sold separately). This must match the setting in the NDP 38,400
Gateway.
Refer to documentation that came with the NDP Gateway
for instructions on where to find this value.
NAFEM DP ID Adjusts the machine-specific ID for use on a NAFEM 1
Data Protocol network. to 5 M
Each device on the network must have a unique ID. 247
Please refer to any documentation that came with other
NDP-compliant devices to verify that all IDs on the network
are unique.
Exit to Params? Exits the Communications Setup menu and returns to the
Parameters menu. Any settings that were changed are M
only saved by choosing the SAVE SETTINGS AND EXIT? option
on the Parameters menu.
Changing communication values typically requires the
machine power to be cycled.
Communications Setup Menu
The Communications Setup Menu Table 2 lists the parameter name, a short description, a list of
possible values the parameter can have, the factory default value based on the specific dishwasher
model and the security level required to access that parameter.