– 6 –
DRAIN CONNECTION
CAUTION: In order to avoid any back pressure in the oven, do not connect solidly to any drain.
Extend the drain line from the 1
1
/2" NPT drain pipe extending from the bottom of the oven at the rear
to an open gap-type drain. Drain piping must have suitable pitch, have appropriate support along its
length, and have no connection to other piping. The material used in the drain line should be heat
resistant to at least 212°F.
ELECTRICAL CONNECTION
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
The wiring diagram is located on the inside surface of the right side panel as you face the oven. Use
copper wire rated for at least 90°C for the connection.
NOTE: Only single-phase fan motors are used on these ovens so there is no need to check direction
of motor rotation. The fan will rotate in the proper direction.
VENT HOOD
Some local codes may require the Combi oven to be located under an exhaust hood. Information on
the construction and installation of ventilating hoods may be obtained from
Vapor Removal from
Cooking Equipment
, NFPA standard No. 96 (latest edition).
ATADLACIRTCELE
ledoMhP/zH/stloV
EZISTIUCRICHCNARB
NOITCETORPDNANOITCETORPDNA
NOITCETORPDNA
NOITCETORPDNANOITCETORPDNA
yticapmAtiucriCmuminiM
eciveDevitcetorPmumixaMeciveDevitcetorPmumixaM
eciveDevitcetorPmumixaM
eciveDevitcetorPmumixaMeciveDevitcetorPmumixaM
SPMASPMA
SPMA
SPMASPMA
H6ECH
3/06/802
3/06/042
3/06/084
53
03
51
H01ECH
F01ECH
3/06/802
3/06/042
3/06/084
07
06
03
H02ECH
3/06/802
3/06/042
3/06/084
09
08
04
F02ECH
3/06/802
3/06/042
3/06/084
521
011
06
.noitidetsetal,07APFN/ISNA,edoClacirtcelElanoitaNehthtiwecnadroccanidelipmoC