Hobart HHFC4c Kitchen Utensil User Manual


 
14
CONTROLS Designer or Two Tier, Model HHFC8 (Case Length: 8 Foot), with Overhead Heater
and Halogen Lighting
One thermostat control (with heating indicator light) adjusts the heaters for the two extreme left and
two extreme right end wells while another thermostat control (and heating indicator light) adjusts the
heaters for the three center wells. One control adjusts the overhead heater for the entire case. One
switch controls all overhead lights. Monitor case temperatures throughout the day as required.
Full Service
Self-Service
CENTER WELLS
THERMOSTAT
WELLS
INDICATOR
LIGHT
OFF
10
9
8
7
6
5
4
3
2
1
END WELLS
THERMOSTAT
WELLS
INDICATOR
LIGHT
OFF
10
9
8
7
6
5
4
3
2
1
FUSE HOLDER
MAIN (ON/OFF)
OVERHEAD
LIGHTS
ON/OFF
OFF
HIGH
LOW
OVERHEAD
HEATER
PL-53655
Overhead Heater Regulates the heating elements to Low, Medium or High settings.
End Wells Thermostat Regulates the well heating elements for both the two extreme left and
two extreme right wells to maintain the set temperature. Settings
range from 1 to 10 (Low to High).
Wells Indicator Light When lit, the well heating element is providing heat to that zone.
Center Wells Thermostat Regulates the well heating elements for the center three wells to
maintain the set temperature. Settings range from 1 to 10 (Low to
High).
Wells Indicator Light When lit, the heating element is providing heat to that zone.
Overhead Lights Turns the overhead halogen lights On or Off.
Fuse Holder Replace fuse with same size and type.
Main Circuit Breaker Turns power to the display case On or Off.
CENTER WELLS
THERMOSTAT
WELLS
INDICATOR
LIGHT
OFF
10
9
8
7
6
5
4
3
2
1
END WELLS
THERMOSTAT
WELLS
INDICATOR
LIGHT
OFF
10
9
8
7
6
5
4
3
2
1
FUSE HOLDER
MAIN (ON/OFF)
OVERHEAD
LIGHTS
ON/OFF
OFF
OVERHEAD
HEATER
PL-53660