Hobart HL120 Mixer User Manual


 
TROUBLESHOOTING
Symptoms Possible Causes
Mixer will not start
Flashing Time Display – See Below
Branch circuit protector is in open position -
check fuse or disconnect switch.
Mixer is overloaded.
Wire cage is not in the closed position.
Bowl is not in closed (mix) position or if Bowl
in not in up position.
Agitator touches bowl
Bowl is not in closed (mix) position.
Improper agitator clearance - see Maintenance
for adjustment procedure.
Agitator is not installed properly
Planetary seal squeaks
Seal requires occasional lubrication - see
Maintenance
Timer displays flashing alarm code
(Ex. “OL1” – Motor overload)
If the error code is flashing – unplug machine
until display is blank then plug back in. If
symptoms still exist, contact your local Hobart
Service office.
SERVICE
If service is needed on this equipment, contact your local Hobart Service office.
1-888-4HOBART
F34922 Rev. B (May 2006) PRINTED IN U.S.A.