Hobart HQCF45 Freezer User Manual


 
– 10 –
BY TEMPERATURE
TYPE: SOFT CHILL
TARGET TEMP: 37
°F
MAIN START
BY TEMPERATURE
TYPE: FREEZE
TARGET TEMP: 0
°F
MAIN START
MAIN MENU
BY TEMP
Chill Cycle is complete when any (or all) product probe(s) reaches the Target Temp.
From the Main Menu, select BY TEMP.
Select the Type: CHILL, SOFT CHILL or FREEZE*.
SEIRESPMETYB
TESERPYROTCAF
PMETTEGRAT
EGNAR
FCQH,CQHLLIHC7F 04OT3**F
FCQH,CQHLLIHCTFOS7F 04OT3**F
FCQHEZEERF0°F 82ot22–°F
55otdednetxeebnacegnaR*F .62egapeesderisedfirosivrepusyb
To adjust the TARGET TEMP: Press or .
Insert probes in product — smart probes sense
temperature of product and are automatically selected.
Close the door.
To begin Chilling, select START.
(MAIN returns to the Main Menu.)
To add more product while chilling: Open door; insert
probe in product; close door; press ADD/REMOVE.
If any probes are
OFF
, select the desired probe(s).
Press CONTINUE.
The chill time displays in the lower left corner —
Hr: Min: Sec.
A probe has reached the target temperature.
Press MUTE or select the ‘done’ probe’s number to
silence the buzzer.
(This step is repeated as each probe reaches the
target temperature; see next page.)
* Some chill types are not available
on all models.
BY TEMPERATURE
TYPE: CHILL
TARGET TEMP: 37
°F
MAIN START
SELECT PROBE:
1 159°F 3
2 154°F
0:00:07 CONTINUE
CHILLING AIR: 14°F
1 159
°F 156°F 3
2 154°F
0:00:19 ADD/REMOVE
CHILLING AIR: 14°F
1 41°F DONE 3
2 44°F
1:16:01 MUTE
MAIN MENU 08:05:01
BY TEMP BY PROD
BY TIME
MORE
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
CHILLING AIR: 14°F
1 159
°F 3
2 154°F
0:00:03 ADD/REMOVE