LOCATION
Good air circulation at the condenser coil in the lower section is necessary to provide proper operation.
The cabinet may be located in any one of the following three ways to assure satisfactory performance.
• The unit can be situated so the lower back section is open to room air, allowing free air discharge.
No side clearance and no top clearance is required. This is the preferred situation and provides
the most effective cooling.
• The unit can be provided with no side clearance, two inches of clearance at the rear, and six inches
of clearance above.
• If the unit is situated with no back clearance and no top clearance, it is necessary to provide either
five inches of clearance on each side or ten inches of clearance on one side of the cabinet.
NOTE: Performance is enhanced when the air going into the condenser coil through the lower front
section is cool. For example, locating the chiller adjacent to an oven would not be recommended.
FEATURES
Shelves (Set of Five)
A set of five shelves is optional on HQC90. A set of five shelves is standard with HQC45 and HQCF45.
Shelf clips are packed with the shelves. For each shelf, insert two front shelf clips and two rear shelf
clips into the pilaster slots at the same height. After installing shelf clips on pilasters, place shelves
on clips.
Optional single shelves are available; up to eight shelves can be installed in the cabinet at one time.
Recommended Pans
Full size 12" x 20" x 2
1
2" pans or 18" x 26" sheet pans are recommended. Pans are not included.
Probes
During a chill cycle, insert probes in pans of food to
monitor temperatures. Probes should not touch
bottom of pan. Place probe in the middle of the food
for best temperature indication.
The Top Probe in the cabinet corresponds to Probe 1
(Fig. 3); the Center Probe is Probe 2; the Bottom
Probe is Probe 3.
Door Switch
When the door is opened, the door switch shuts off fans and DOOR OPEN displays. If the door is open
for 30 seconds, the refrigerant valve closes. If the door is open for 120 seconds (or the
DOOR OPEN
time setting on page 25), a buzzer sounds. After the door closes, timer and chiller operations resume.
Fan Door Switch
A fan door switch also shuts the fans and refrigerant valve off if the metal fan grill is not properly
fastened in place. A notice displays: WARNING !!! FAN DOOR IS OPEN. CALL HOBART SERVICE
FOR REPAIR. If the operator and supervisor cannot shut the interior fan door, contact Hobart Service.
The chiller will not operate with the fan door open.