– 7 –
OPERATION
WARNING: THE EXHAUST HOOD AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN
OPERATING, CLEANING OR SERVICING THE EXHAUST HOOD.
CONTROLS
On-Off Switch — Located on the left side behind the hood pull. Turns power to the
exhaust hood on and off. When turned ON, the reset switch must be
pressed to start blowers.
Green Interlock Light — When lit, indicates that all hood interlock switches are closed and
power is applied to the fryer.
Red ANSUL
®
Light — When lit, indicates that the fire suppression system is not cocked and/
or charged.
Red FIP (Filter-In-Place) — When lit, indicates that one or more filters are not properly installed.
Sail Light — When lit, indicates the exhaust blower is not operating and moving an
adequate volume of air.
Reset Pushbutton Switch — Momentarily overrides the sail switch to allow the exhaust blower to
start.
CLEANING
WARNING: DISCONNECT (UNPLUG) ELECTRIC POWER SUPPLY BEFORE CLEANING.
Clean the air filters and hood weekly (Fig. 5)
Charcoal Filter
Air Filter
Grease Filter
Tray
PL-50755
Fig. 5
1. Push in the bottom of the Grease Filter; tilt the top of the filter forward using the handles; and
remove the filter. Scrub the Grease Filter in warm soapy water; rinse, drain and towel dry.
2. Push in the bottom of the Air Filter; tilt the top of the filter forward; and remove the filter. Scrub
the Air Filter in warm soapy water; rinse, drain and towel dry.