– 14 –
OPTIONAL EQUIPMENT CONNECTIONS — Detergent, Rinse Aid, Sanitizer Dispensers
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Detergent Dispenser (Fig. 10)
Terminals DPS1 and DPS2 are supplied with controlled machine line voltage. They are ON during the
wash cycle and OFF between cycles or when the machine power supply is OFF. Maximum rating for
detergent dispenser connected to DPS1 and DPS2 is 1.5 Amps at line voltage. Check the machine
supply voltage and use corresponding feeder transformer voltage. Use UL listed 600 volt minimum
insulated wire to make the necessary connections. Do not use bell wire, lamp cord, or similar type wire.
Splice connections, if required, must be made in the feeder transformer junction box — not in the main
control box. Remove
7
/8" diameter cap plug(s) for
1
/2" trade size conduit fittings from the side of the
control box. Strain relief fittings must be provided for all wiring.
Rinse Aid and / or Sanitizer Dispenser (Fig. 10)
Terminals RPS1 and RPS2 are supplied with controlled machine line voltage and are ON during the
rinse cycle only. and OFF between cycles or when machine power supply is OFF. Maximum rating
for rinse aid dispenser connected to RPS1 and RPS2 is 1.5 Amps at line voltage. Check the machine
supply voltage and use corresponding feeder transformer voltage. Use UL listed 600 volt minimum
insulated wire to make the necessary connections. Do not use bell wire, lamp cord, or similar type wire.
Splice connections, if required, must be made in the feeder transformer junction box — not in the main
control box. Remove
7
/8" diameter cap plug(s) for
1
/2" trade size conduit fittings from the side of the
control box. Strain relief fittings must be provided for all wiring.
Fig. 10
— DPS1
— DPS2
— RPS1
— RPS2
DETERGENT
DISPENSER
TRANSFORMER
PRIMARY
SECONDARY
RINSE AGENT
DISPENSER
CHEMICAL
SANITIZER
DISPENSER
MAIN CONTROL BOX
TRANSFORMER
PRIMARY
SECONDARY