If the set temperature difference E03 is negative, an alarm is given
if it is too cold in the refrigerated area,
e.g. E03 = –10 K, cold store setpoint = –18 °C
alarm at –28 °C in refrigerated area.
If the set temperature difference E03 is positive, the alarm is given
if it is too warm in the refrigerated area,
e.g. E03 = +10 K, cold store setpoint value = –18 °C
alarm at –8 °C in the refrigerated area.
Attention: any change of the cold store setpoint valve changes also
the alarm temperature.
If E03 is set to 0, no alarm will be given.
PCR-300RC only:
E2’1 1st defrost time
–––
(none), 00.1 to 23.5 hours
–––
(none)
E2’2 2st defrost time
–––
(none), 00.1 to 23.5 hours 01’0 hours
E2’3 3st defrost time
–––
(none), 00.1 to 23.5 hours 07’0 hours
E2’4 4st defrost time
–––
(none), 00.1 to 23.5 hours 13’0 hours
E2’5 5st defrost time
–––
(none), 00.1 to 23.5 hours 19’0 hours
E2’6 6st defrost time
–––
(none), 00.1 to 23.5 hours
–––
(none)
The time is entered in increments
of 10 minutes in each case.
Caution: The times must be entered
in ascending order.
Exiting programming mode: Press the key after the last level has
been entered.
6.6 Setting the time (PCR-300RC only)
¼ Press and hold down the and keys at the same time for
approx. 5 seconds to access the first programming level
(Display: E00).
¼ Setting: Press and hold down the key and change
the time to the current time using the or key
(increments of 10 minutes).
Display Setting range Preset
E00 Time 00.0 to 23.5 hours 12’0 hours
Exiting programming mode:
Press the key several times.