Honeywell VNT5150H1000 Ventilation Hood User Manual


 
Specications(continued)
External Static
Pressure
Net Supply Air Flow
Gross Air Flow
Supply Exhaust
Pa in. W.C. L/s CFM L/s CFM L/s CFM
25 0.1 117 248 118 250 130 277
50 0.2 108 229 109 231 119 253
75 0.3 102 218 103 220 110 234
100 0.4 94 200 95 202 101 216
125 0.5 85 181 86 183 92 197
150 0.6 77 163 78 165 82 175
175 0.7 69 146 70 148 71 151
200 0.8 61 129 61 131 60 128
225 0.9 52 110 52 111 49 104
250 1.0 45 96 46 97 40 86
Supply Temperature Net Supply Air Flow
Average
Power
Sensible
Recovery
Apparent
Sensible
°C °F L/s CFM Watts Efficiency % Effectiveness %
Heating
0 32 55 118 106 61 71
0 32 75 160 132 58 65
0 32 87 185 150 55 62
-25 -13 57 120 105 58 72
VNT5200H1000VentilationPerformance
VNT5200H1000EnergyPerformance
ERV/HRVVentilationSystems69-2480EF—01
6
VNT5200H1000
AIR FLOW (L/S)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0 50 100 150 200 250 300
0
25
50
75
100
125
150
175
200
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
EXTERNAL
STATIC
PRESSURE
(IN. W. C)
NET SUPPLY AIR FLOW
AIR FLOW (CFM)
EXTERNAL
STATIC
PRESSURE
(PA)
M32354