Honeywell VNT5200E1000 Ventilation Hood User Manual


 
InstalltoFitYourApplication(continued)
B
Exhaust at the Source and Supply in the Return
Thisapplicationusesadevotedductsystemfortheexhaustingofstaleairaccumulatedinthehome.
Thefreshairisintroducedintothereturnairductandisdistributedthroughthehomebytheexisting
supplyairductworkoftheforcedairsystem.
Makesurewhenusingthisapplicationthatyourfreshairductconnectiontotheforcedairsystemreturn
airductisatleast3feetfromtheforcedairsystem.Youshouldcheckwithyourlocalcodeortheforced
airsystem’smanufacturer.
Theforcedairsystem’sblowerdoesnothavetorunwhentheunitisoperating,butisrecommendedfor
maximumeffectiveness.
NOTE: Fortheminimumdistancebetweenthefreshairconnectionandtheforcedairsystem,check
withyourlocalbuildingcodesandforcedairsystemmanufacturer.
NOTE: Fordwellingswithmultipleforcedairsystems,HoneywellrecommendsoneERV/HRVunitper
system.
NOTE: RefertotheWiringsection(beginningonpage18)forinstructionstoconnecttheunittooperate
theforcedairsystemwiththeERV/HRVunit.
TO LIVING
SPACE
HRV / ERV
STALE AIR FROM LIVING SPACE,
SUCH AS FROM BATHROOM
OR KITCHEN
FORCED AIR
SYSTEM
3 FEET
6 FEET
18 INCHES
M28984
ERV/HRVVentilationSystems69-2480EF—01 11