Hoover 33800318 Cooktop User Manual


 
7
INSTALLATION: «GAS CONNECTION»
The hob can be built-in ; it is in class 3 (in compliance with gas regulations EN 30.1.1) ;
adjoining furniture should not be higher than the level of the hob.
This appliance is not connected to an evacuation device for the products of combustion.
It must be installed and connected in compliance with the norms in force in the country of
installation. Particular attention should be given to the availability of ventilation.
The turnover of air necessary for combustion is a minimum of 2 m3/h per kW of power.
Gas connection should be carried out in compliance with the norms in force in the country
of installation. A stop tap, a regulator valve or a release valve for propane gas, should be
fitted to the gas supply pipe. Use only taps, regulator valves, connectors and flexible
hoses with the official mark of approval of the country of installation.
Built-in appliance
Butane Rigid - Flexible pipe with mechanical connectors (1) -
Propane Rigid - Flexible pipe with mechanical connectors (1) -
Natural Rigid - Flexible pipe with mechanical connectors (1) -
(1) on condition that the hose is accessible along the whole of its length it should be
located so it cannot be reached by naked flame or affected by combustion gases. Neither
should it be near hot parts of the hob nor anywhere where hot spillages could affect it.
2 POSSIBLES MEANS OF CONNECTION :
Fit the appliance with the cylindrical or the conical gas adaptor, in accordance to
the installation Country standards, and then proceed to the connection, two possibilites:
• CONNECTION BY RIGID PIPE
Connect directly to the threaded end of the inlet pipe.
• CONNECTION BY FLEXIBLE PIPE WITH MECHANICAL CONNECTOR
Screw the nuts of the flexible pipe directly on to the inlet pipe at one end and the
gas supply stop tap at the other.
We recommend this type of connection.
Cylindrical
seal
conical
Conical gas adaptor