II. Installation Instructions
WARNING
• The appliance must be installed in accordance with applicable national, state, and
local codes and regulations.
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews
are securely in place after installation. Make sure that none have fallen into the
storage bin.
A. Checks Before Installation
• Visually inspect the exterior of the shipping container and immediately report any
damage to the carrier. Upon opening the container, any concealed damage should also
be immediately reported to the carrier.
• Remove the shipping carton, tape, and packing material. If any are left in the appliance,
it will not work properly.
• Remove the package containing the accessories.
• Remove the protective plastic lm from the panels. If the appliance is exposed to the
sun or to heat, remove the lm after the appliance cools.
• See the nameplate inside the storage bin, and check that your voltage supplied
corresponds with the voltage specied on the nameplate.
B. Location
1. General
The appliance is approved for indoor or outdoor use.
NOTICE
• Normal operating ambient temperature must be within 45°F to 100°F (7°C to
38°C); Normal operating water temperature must be within 45°F to 90°F (7°C to
32°C). Operation of the appliance, for extended periods, outside of these normal
temperature ranges may affect appliance performance.
• The appliance will not work at sub-freezing temperatures. To prevent damage
to the water supply line, drain the appliance if the air temperature is going to go
below 32°F (0°C). See "V. Preparing the Appliance for Periods of Non-Use."
• The appliance should not be located next to ovens, grills, or other high heat producing
equipment.
• The location must provide a rm and level foundation for the appliance.
• The appliance requires no side or top clearance. But allow enough space at rear for
water supply and drain connections and at least 15" (38 cm) clearance at front.
• The appliance must be at oor level on a nished oor even if under a cabinet. In areas
where water damage is a concern, install in a contained area with a oor drain.