10
H. Startup
CAUTION
1. All parts are factory-adjusted. Improper adjustments may result in failure.
. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to
prevent damage to the compressor.
1) Clean the storage bin.
) Open the water supply line shut-off valve.
3) Make sure the power switch on the control box is in the "OFF" position. Plug the unit
into the electrical outlet.
4) Move the ush switch
to the "ICE" position and move
the
power switch to the
"ON" position to start the
automatic icemaking process
.