5
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 8.5 RLA 51 LRA
GEAR MOTOR 120 V 1.6 FLA 1/6 HP
FAN MOTOR 115 V 0.85FLA 50W
OTHER 120 V 0.03A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *426 (193) 407 (185) 387 (176)
Reference without *marks 80 368 (167) 350 (159) 333 (151)
90 317 (144) *310 (141) 287 (130)
100 273 (124) 260 (118) *244 (111)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 956 (7.4) 880 (5.0)
POTABLE WATER 37 (12) 51 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 21"-7/8" x 27-3/8" x 21-61/64" (556 x 696 x 557.7mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 150 lbs. ( 68 kg ), Shipping 175 lbs. ( 80 kg )
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/6 HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Infrared Sensor
COMPRESSOR Hermetic, Model RS43C1E-CAA-219
CONDENSER Air-cooled, Fin and tube type
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, 1 lb. (455 g)
DESIGN PRESSURE High 427 PSIG, Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Internal Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker or Fuse
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - REQUIRED Ice Storage Bin
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
2. F-450MAH-C
We reserve the right to make changes in specifications and design without prior notice.