Hoshizaki F-80 I MAH (-c) Ice Maker User Manual


 
30
F-801MWH
We reserve the right to make changes in specifications and design without prior notice.
APPROXIMATE Ambient Water Temp. (F)
ICE PRODUCTION Temp. (F)
PER 24 HR. 70 * 720 (327) 693 (315) 677 (307)
80 661 (300) 646 (293) 630 (286)
90 616 (279) * 605 (274) 587 (266)
lbs./day ( kg/day) 100 573 (260) 560 (254) * 520 (236)
APPROXIMATE ELECTRIC 70 * 1076 -- 1076 -- 1076 --
CONSUMPTION 80 1076 -- 1077 -- 1077 --
90 1077 -- *1078 -- 1076 --
watts 100 1074 -- 1071 -- *1069 --
APPROXIMATE WATER 70 * 306 (1158) 397 (1504) 631 (2387)
CONSUMPTION PER 24 HR. 80 318 (1205) 415 (1571) 666 (2520)
(TOTAL) 90 331 (1251) * 433 (1638) 704 (2666)
gal. / day (l/day) 100 344 (1304) 457 (1728) * 778 (2944)
EVAPORATOR OUTLET TEMP. 70 * 17 (-8) 17 (-8) 18 (-8)
°F (°C) 80 19 (-7) 19 (-7) 20 (-7)
90 20 (-7) * 20 (-7) 20 (-7)
100 20 (-7) 20 (-7) * 21 (-6)
HEAD PRESSURE 70 * 265 (18.6) 265 (18.6) 266 (18.7)
80 265 (18.6) 265 (18.6) 266 (18.7)
90 265 (18.6) * 265 (18.6) 266 (18.7)
PSIG (kg/cm
2
G)
100 265 (18.6) 265 (18.6) * 266 (18.7)
SUCTION PRESSURE 70 * 42 (3.0) 43 (3.0) 44 (3.1)
PSIG (kg/cm
2
G) 80 42 (3.0) 43 (3.0) 44 (3.1)
90 42 (3.0) * 43 (3.0) 44 (3.1)
100 42 (3.0) 43 (3.0) * 44 (3.1)
Note: The data without *marks should be used for reference.
HEAT OF REJECTION FROM COMPRESSOR 1050 BTU/h (AT 90°F / WT 70°F)
WATER FLOW FOR CONDENSER 15 gal/h (AT 90°F / WT 70°F)
PRESSURE DROP OF COOLING WATER LINE Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER
50 70 90
5155 BTU/h (AT 90°F / WT 70°F)