Hoshizaki F-80 I MAH (-c) Ice Maker User Manual


 
32
F-801MWH-C
We reserve the right to make changes in specifications and design without prior notice.
APPROXIMATE Ambient Water Temp. (F)
ICE PRODUCTION Temp. (F)
PER 24 HR. 70 * 645 (293) 620 (281) 608 (276)
80 596 (270) 585 (265) 574 (260)
90 563 (255) * 550 (249) 541 (246)
lbs./day ( kg/day) 100 531 (241) 521 (236) * 485 (220)
APPROXIMATE ELECTRIC 70 * 1083 -- 1082 -- 1081 --
CONSUMPTION 80 1080 -- 1078 -- 1077 --
90 1076 -- *1075 -- 1073 --
watts 100 1072 -- 1070 -- *1068 --
APPROXIMATE WATER 70 * 276 (1046) 342 (1294) 579 (2192)
CONSUMPTION PER 24 HR. 80 287 (1086) 354 (1339) 605 (2291)
(TOTAL) 90 296 (1119) * 368 (1392) 633 (2397)
gal. / day (l/day) 100 305 (1156) 381 (1442) * 693 (2622)
EVAPORATOR OUTLET TEMP. 70 * 20 (-7) 20 (-7) 21 (-6)
°F (°C) 80 21 (-6) 21 (-6) 21 (-6)
90 21 (-6) * 21 (-6) 21 (-6)
100 21 (-6) 21 (-6) * 22 (-6)
HEAD PRESSURE 70 * 263 (18.5) 263 (18.5) 264 (18.6)
80 263 (18.5) 263 (18.5) 264 (18.6)
90 263 (18.5) * 263 (18.5) 264 (18.6)
PSIG (kg/cm
2
G)
100 263 (18.5) 263 (18.5) * 264 (18.6)
SUCTION PRESSURE 70 * 46 (3.2) 46 (3.3) 47 (3.3)
PSIG (kg/cm
2
G) 80 46 (3.2) 46 (3.3) 47 (3.3)
90 46 (3.2) * 46 (3.3) 47 (3.3)
100 46 (3.2) 46 (3.3) * 47 (3.3)
Note: The data without *marks should be used for reference.
50 70 90
13 gal/h (AT 90°F / WT 70°F)
Less than 7 PSIG
5155 BTU/h (AT 90°F / WT 70°F)
WATER FLOW FOR CONDENSER
PRESSURE DROP OF COOLING WATER LINE
HEAT OF REJECTION FROM CONDENSER
HEAT OF REJECTION FROM COMPRESSOR 1050 BTU/h (AT 90°F / WT 70°F)