Hoshizaki HWR68A(-D) Freezer User Manual


 
40
g. Clogged Filter Sensor Malfunction Alarm (E9)
If the input from the clogged lter sensor is below the clogged lter sensor open circuit
detection point (equivalent to -7.6°F (-°C)), "E9" is displayed. "E9" is also displayed
when input from the clogged lter sensor is above the clogged lter sensor short circuit
detection point (equivalent to 186.8°F (86°C)) for 10 minutes or more.
Note:
• If this alarm appears, rst make sure that the sensor is properly connected.
• A short circuit can be detected immediately by turning on the power while pressing
the button. In this case, "E9" will be displayed immediately if a short circuit is
detected.
Reset Options
The alarm automatically resets when one of the following conditions is met:
• The input from the clogged lter sensor exceeds the open circuit detection point
(equivalent to -7.6°F (-°C)).
• The input from the clogged lter sensor drops below the short circuit detection point
(equivalent to 186.8°F (86°C)).
• A functioning clogged lter sensor (gray) is installed.
Possible Causes
• Trouble with the clogged lter sensor (gray).