Hoshizaki KM-1300SAH3 Refrigerator User Manual


 
5
I. Specifications
1. Icemaker
KM-1300SAH
AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE 12.6 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY 20 A
MAXIMUM FUSE SIZE 20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *1283 (582) 1242 (563) 1135 (515)
Reference without *marks 80 1252 (568) 1188 (539) 1053 (478)
90 1242 (563) *1143 (518) 1017 (461)
100 1203 (546) 1114 (505) 902 (409)
SHAPE OF ICE Crescent Cube
ICE PRODUCTION PER CYCLE 30.1 lbs. (13.7 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITY N/A
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 2334 (4.9) 2180 (0.0)
WATER gal./24HR (gal./100 lbs.) 327 (28.6) 697 (54.3)
EXTERIOR DIMENSIONS (WxDxH) 48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISH Stainless Steel, Galvanized Steel (Rear)
WEIGHT Net 275 lbs. ( 125 kg ), Shipping 315 lbs. ( 143 kg )
CONNECTIONS - ELECTRIC Permanent - Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 3/4" FPT
- CONDENSATE DRAIN 3/8" OD Pipe
CUBE CONTROL SYSTEM Float Switch
HARVESTING CONTROL SYSTEM Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL Timer Controlled. Overflow Pipe
COOLING W ATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model CS14K6E-PFV-237
CONDENSER Air-cooled, Fin and Tube Type
EVAPORATOR Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, 3 lb. 14 oz. ( 1750 g )
DESIGN PRESSURE High 467 PSIG, Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch
ACCESSORIES -SUPPLIED N/A
-REQUIRED Ice Storage Bin
OPERATING CONDITIONS VOLTAGE RANGE 187 - 253 V
AMBIENT TEMP. 45 -100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
We reserve the right to make changes in specifications and design without prior notice.