Hoshizaki KM-2000SWH3 Ice Maker User Manual


 
22
10. START UP10. START UP
10. START UP10. START UP
10. START UP
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
1. All parts are factory-adjusted. Improper adjustments may result in failure.
2. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the Compressor.
3. Do not operate the unit in the “WASH” position without water in the Water
Tank. This will cause damage to the Water Pump seal.
1) Open the Water Supply Line Shut-off Valve.
2) Remove the Front Panel.
3) Move the Control Switch, on the Control Box, to the “ICE” position.
4) Replace the Front Panel in its correct position.
5) Turn on the power supply, and allow the Water Tank to fill with water and the icemaker
to operate for a total of 10 minutes.
Note: If miswiring causes excessive voltage on the Controller Board, the High Voltage
Cut-out shuts down the circuit in 3 seconds and the icemaker automatically stops.
When the proper supply voltage is resumed, the icemaker automatically starts
running again.
6) Turn off the power supply, and remove
the Front Panel.
7) Remove the Insulation Panel. Remove
the Cap located on the front bottom part
of the Ice Dropping Hole. Drain the
Water Tank. See Fig. 13.
8) Replace the Cap, Insulation Panel and
Front Panel in their correct positions.
9) Clean the Storage Bin.
10) Turn on the power supply, and start the
automatic icemaking process.
Fig. 13Fig. 13
Fig. 13Fig. 13
Fig. 13