78
6. KM-600MAH
70/21 592 269 566 257 516 234
80/27 572 260 532 241 474 215
90/32 566 257 503 228 447 203
lbs./day kg./da
y
100/38 551 250 490 222 396 180
70/21
80/27
90/32
watts 100/38
70/21 259 0.98
212 0.80 191 0.72
80/27 223 0.84 150 0.57 154 0.58
90/32 212 0.80 99 0.38 92 0.35
gal./day m
3
/day
100/38 160 0.61 97 0.37 85 0.32
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 238 16.7
259 18.2 290 20.4
80/27 254 17.9 287 20.2 319 22.4
90/32 259 18.2 310 21.8 342 24.1
PSIG kg/cm
2
G
100/38 266 18.7 318 22.3 372 26.2
70/21 55 3.9 56 4.0 58 4.1
80/27 56 3.9 58 4.0 60 4.2
90/32 56 4.0 59 4.1 61 4.3
PSIG kg/cm
2
G
100/38 57 4.0 59 4.2 62 4.4
2.0
TOTAL HEAT OF REJECTION FROM CONDENSER 9,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
3.4
2.9
3.6 2.0
41
35
36
40
1102
1137
1195
1200
38
42
44
48
1073
1084
1142
1190
1191
1040
1073
1084
33
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10 70/21 90/32
34
35
38
2.0
4.2
2.9
3.6
2.7
2.0
3.7
ENG.F-011.1.0205
Note:
1. Pressure data is recorded at 5 min. into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specications and design without prior
notice.