80
8. KM-650MWH
70/21 661 300 649 294 616 280
80/27 652 296 633 287 591 268
90/32 649 294 620 281 581 264
lbs./day kg./da
y
100/38 637 289 611 277 546 248
70/21
80/27
90/32
watts 100/38
70/21 744 2.81
784 2.97 1169 4.42
80/27 775 2.93 838 3.17 1405 5.32
90/32 784 2.97 882 3.34 1380 5.22
gal./day m
3
/day
100/38 985 3.73 999 3.78 1838 6.96
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 239 16.8
239 16.8 246 17.3
80/27 239 16.8 240 16.9 250 17.6
90/32 239 16.8 240 16.9 249 17.5
PSIG kg/cm
2
G
100/38 243 17.1 242 17.0 257 18.1
70/21 46 3.2 47 3.3 50 3.5
80/27 47 3.3 48 3.4 52 3.7
90/32 47 3.3 49 3.5 53 3.7
PSIG kg/cm
2
G
100/38 48 3.4 50 3.5 56 4.0
TOTAL HEAT OF REJECTION FROM COMPRESSOR 1,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER 73 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE less than 10 PSIG
70/21 90/32
28
29
30
2.4
4.0
3.0
3.5
2.9
1076
1074
28
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
1092
1098
1086
11101086
1074
1066
1060
1066
1080
29
29
30
HARVEST CYCLE TIME
HEAD PRESSURE
31
32
33
35
2.4
TOTAL HEAT OF REJECTION FROM CONDENSER 9,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
31
3.7
SUCTION PRESSURE
3.3
2.9
3.5 2.3
2.1
ENG.F-011.1.0205
Note:
1. Pressure data is recorded at 5 min. into freezing cycle. The data not in bold
should be used for reference only.
2. We reserve the right to make changes in specications and design without prior
notice.