Hoshizaki KM-630MWF Ice Maker User Manual


 
31
To Freeze Cycle
To Stand-by Cycle (When Control Sw. is turned OFF, Pressure Sw. is OFF, or Thermistor Temp. exceeds t1.)
From Freeze Cycle
Control
Sw. in
WASH
Max.
20 min
*1 The Pump Motor waits for 2 seconds before starting a drain cycle. See “II. 2. [d] CONTROLS AND
ADJUSTMENTS.”
*2 The icemaker does not complete a defrost cycle in the first 2 or 3 minutes. See “II. 2. [d] CONTROLS AND
ADJUSTMENTS.”
*
2
*
2
*
1
Min. Max. Max.
3 min 6 min 6 min