Hoshizaki KMH-2000SRH/3 Ice Maker User Manual


 
23
4) Connect the fan motor leads in the junction box of the remote condenser unit to the fan
motor leads in the fan motor junction box of the icemaker. Use wire of an appropriate
gage and outdoor rating.
5) Replace the junction box covers and the louver panel in their correct positions.
Fig. 14
Screws
Louver Panel
Junction Box
Cover
Remote Condenser Unit Icemaker
Screw
Fan Motor Junction
Box Cover
Fig. 15
Upper Remote
Condenser Unit
Screws
Lower Remote
Condenser Unit
Screws
7. Stacking Remote Condenser Units
1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower. See Fig. 15.
3) Secure the upper remote condenser unit to the lower remote condenser unit with the
4 screws provided.
4) Install refrigerant lines and make electrical connection as described earlier in this
section.