8. START UP
CAUTION
1. All parts are factory-adjusted. Improper adjustments may result in failure.
2. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the Compressor.
3. Do not operate the unit in the “WASH” position without water in the Water
Tank. This will cause damage to the Water Pump seal.
1) Open the Water Supply Line Shut-off Valve.
2) Remove the Front Panel.
3) Move the toggle Control Switch, on the Control Box, to the “ICE” position.
4) Replace the Front Panel in its correct position.
5) Turn on the power supply and allow the Water Tank to fill with water and the icemaker
to operate for a total of 10 minutes.
6) Remove the Front Panel and the Bin Control Cover and turn the control switch to “OFF”.
7) Check to assure that the Bin Switch shuts the unit down.
a) Turn the control switch to “ICE”.
b) Allow the unit to cycle into the freeze mode. This occurs when the
pump motor starts to supply water upwards, through the supply tube.
After 1-2 minutes in freeze, move the bin switch paddle fully to the right
See Fig. 5.
c) The unit should shut down within 3-5 seconds.