Hoshizaki KML-450MAH Ice Maker User Manual


 
16
9. PREPARING THE ICEMAKER FOR LONG STORAGE
CAUTION
When shutting off the icemaker for an extended time, drain out all water from
the water line and remove the ice from the Storage Bin. The Storage Bin
should be cleaned and dried. Drain the icemaker to prevent damage to the
water supply line at sub-freezing temperatures, using air or carbon dioxide.
Shut off the icemaker until the proper ambient temperature is resumed.
• When the icemaker is not used for two or three days, it is sufficient to only move the Control
Switch to the “OFF” position, unless the icemaker will be at sub-freezing temperatures.
[1] On water-cooled model only, first remove the water from the water-cooled condenser:
1) Turn off the power supply.
2) Remove the Front Panel.
3) Move the Control Switch, on the Control Box, to the “OFF” position.
4) Wait 3 minutes.
5) Move the Control Switch to the “ICE” position.
6) Replace the Front Panel and turn on the power supply.
7) Allow 5 minutes for the icemaker to fill with water and the Water Pump to start operating.
8) Close the Water-cooled Condenser Water Supply Line Shut-off Valve. See Fig. 4.
9) Open the Drain Valve for the water-cooled condenser water supply line.
10) Allow the line to drain by gravity.
11) Quickly attach compressed air or carbon dioxide supply to the Condenser Water Line
Drain Valve.
12) Blow the water-cooled Condenser out using compressed air or carbon dioxide until
water stops coming out.