Hoshizaki SRH/3 KM-2100SWH3 Ice Maker User Manual


 
30
8) Normal Harvest Cycle – Same as the initial harvest cycle. Return to step 5a) above.
Note: Appliance continues to cycle until MBC is satised or power is switched off. The
appliance always restarts at the 1-min. ll cycle.
9) Shutdown: "G" Control Board
When the appliance is running, hold ice in contact with the thermostatic bulb. BC
switch opens within 10 sec., shutting down the appliance. BC is factory set, and
generally no adjustment is required. However, adjustment may be needed in some
conditions, particularly at higher altitude locations. CB red K4connector must have
the jumper in place. When the jumper is in place, the green "BC CLOSED" LED
remains on. If the jumper is not in place, yellow "BC OPEN" LED turns on and the
icemaker turns off and remains off until the jumper is replaced in its original position.
Diagnosis: See "II.D. Bin Control Check."
Legend: BC–bin control; CB–control board; Comp–compressor; CR–compressor relay;
CT–control transformer; CV–check valve; FM–fan motor; FMR–fan motor remote;
FS–oat switch; HGV–hot gas valve; HM–headmaster (C.P.R.); HPS–high-pressure
switch; LLV –liquid line valve; MC–magnetic contactor; PM–pump motor;
TXV–thermostatic expansion valve; WRV–water regulating valve; WV–inlet water
valve