Hoshizaki SRH/3 KM-2100SWH3 Ice Maker User Manual


 
48
4. Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump-out frequency control is factory set. Generally no adjustment is required.
However, where water quality is bad and the icemaker needs a pump-out more often, the
pump-out frequency can be adjusted. The pump-out frequency control can be set to have
a pump-out occur every cycle, or every 2, 5, or 10 cycles.
Timing of the rst pump-out is dependent on the control board. On "E" control boards, the
rst pump-out is after the rst freeze cycle. On "G" control boards, the rst pump-out is
dependent on S4 dip switch 5 & 6. See the table below.
"E" & "G" Control Board 1st Pump-Out
S4 Dip Switch Setting
Pump-Out
Frequency
"E" Control Board "G" Control Board
No. 5 No. 6
OFF OFF Every cycle After 1st freeze cycle After 2nd freeze cycle
ON OFF Every 2 cycles After 3rd freeze cycle
OFF ON Every 5 cycles After 6th freeze cycle
ON ON Every 10 cycles After 11th freeze cycle
5. Bin Control Selector or Harvest Pump Timer Operation (S4 dip switch 7)
Depending on the control board, S4 dip switch 7 is used for either bin control selection or
harvest pump timer operation.
• "E" Control Board: Bin Control Selector (thermostatic or mechanical).
• "G" Control Board: Harvest Pump Timer Operation.
a) Bin Control Selector: "E" Control Board
NOTICE
Do not adjust. This dip switch must be left in the factory default position or the
icemaker will not operate correctly.
When set to on position on an icemaker with a thermostatic bin control, a 5-beep alarm
sounds (open circuit) and the icemaker does not operate.
"E" Control Board
S4 Dip Switch Setting
Bin Control
No. 7
ON Mechanical (requires resistor wire harness)
OFF Thermostatic