Hoshizaki SWH3-M KM-1601SAH/3 Ice Maker User Manual


 
45
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions for both the "E" and "G"
control boards:
a) "E" and "G" Control Board without Harvest Pump Timer Operation
Model
Auxiliary
Code
Water Valve
Part Number
Code on
Water
Valve
S4 Dip Switch No.
1 2 3 4 5 6 7 8 9 10
KM-1601SWH/3
All
OFF OFF OFF OFF ON ON OFF OFF OFF ON
KM-1601SRH/3 R-0, R-1,
some S-1
3U0111-02
(8 l/min)
J248-032
ON OFF ON OFF OFF OFF OFF OFF OFF OFF
Some S-1 3U0111-01
(15 l/min)
J248-030
ON OFF OFF OFF ON ON OFF OFF OFF OFF
S-2 & later 4A1176-04 (11 l/min)
V-1 (M) & later 4A5251-04 (11 l/min)
KM-1900SAH/3
KM-1900SWH/3
KM-2100SWH3
KMH-2000SWH/3
KMH-2000SRH3
All OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
KM-1900SRH/3
KM-2100SRH3
All ON OFF ON ON OFF OFF OFF OFF ON OFF
KM-2500S_H3
All OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
KMH-2000SRH
All OFF OFF OFF OFF OFF OFF OFF OFF ON ON