Hotpoint GE640X Cooktop User Manual


 
GB
5
Burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal
Power
kW
(p.c.s.*)
Thermal
Power
kW
(p.c.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
Flow*
g/h
Thermal
Power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
g/h
Red. Nom. (mm) (mm) *** ** Nom. (mm)
Fast
(Large) (R)
100 0,70 3,00 41 86 218 214 3,00 116 286
Reduced Fast
(RR)
100 0,70 2,60 41 80 189 186 2,60 110 (Y) 248
Semi Fast
(Medium) (S)
75 0,40 1,65 30 64 120 118 1,65 96 157
Auxiliary
(Small) (A)
55 0,40 1,00 30 50 73 71 1,00 79 95
Triple Crown
(TC)
130 1,30 3,30 57 87 240 236 3,60 131 343
Supply
pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar-dry gas
** Propane P.C.S. = 50.37 MJ/kg.
*** Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3
R
A
S
S
RR
A
S
TCTC
GE 640 GE 641 T
GE 640 TX
DATA PLATE
Electrical
connections
220-240V ~ 50/60Hz
This appliance conforms to the
following European Economic
Community directives:
-73/23/EEC dated 19/02/73 (Low
Voltage) and subsequent
amendments
- 89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 90/336/EEC dated 29/06/90
(Gas) and subsequent
amendments.
- 2002/96/EC