TABLE OF CHARACTERISTICS
Dimensions *
width 43.5 cm
height 32 cm
depth 41.5 cm
Volume * 58 l
Electrical
connections
voltage: 220-240V ~ 50Hz
maximum power absorbed
2800W
ENERGY LABEL *
Directive 2002/40/EC on the label
of electric ovens.
Standard EN 50304
Declared energy consumption for
Forced convection Class
heating mode: Gratin
This appliance conforms to the
following European Economic
Community directives: 73/23/EEC
dated 19/02/73 (Low Voltage)
and subsequent amendments -
89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments.
2002/96/EC
* Without removable
g
uide rails
Electrical Connection
Electrical connection
The electrical connection to the mains must be made
on the appliance. The power voltage and frequency
are as indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
Using a screwdriver, press on the tabs situated
on each side of the terminal board cover.
Pull open the terminal board cover.
To connect the power supply cable, proceed as
follows:
_ Unscrew the cable clamp screw and the contact
screws L-N-$.
Fasten the wires beneath the screwheads using
the following colour scheme: Blue (N) Brown (L)
Yellow-Green$
Fasten the power supply cable in the
corresponding cable clamp and close the cover.
Electrical Connection:
Voltage Frequency: 230
V-1+N 50Hz
Fuse Section: 16A
Supply cable:
3x1.5mm
2
You can connect your oven to the system means of
a terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which
is long enough to allow you to take the oven out of
its recess in the event of maintenance operations
(only use HAR - H 05 - RRF quality cables fitted with
a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unpl ug the appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly dangerous.
! After connecting the appliance
to the flexible
cable, tighten all the screws on the terminal
board.
42