Data badge
Lower part of front frame and rear of
appliance.
Pressure setting
Cat I
2H (GB/IE) G20 @ 20mbar
Gas category
I
2H
Appliance class
Class 3
Ignition
Mains operated re-ignition generator
Oven light
25W
Electrical supply
220 - 240V ~ 50Hz, 44W
Grill
Nominal Rate Qn 2.4kW
Injector 1.12mm
Spark gap 3 - 4mm
Oven
Bray type burner, sheet steel body,
stainless steel flame strip
Nominal Rate Qn 2.5kW
Injector 1.25mm
Spark gap 3 - 4mm
Thermostat bypass 50
Oven injector - If the injector is
removed or replaced for any reason, it
is mandatory to apply Hylomar PL32
or Plasticol X10 sparingly to the thread
prior to (re) fitting.
Maximum heat input
∑Qn 2.5kW
Countries of destination
GB - Great Britain, IE - Ireland
30
Technical Data
The cooling fan
The cooling fan helps to keep the
exterior cool during normal use.
When a burner is operated, you
should hear the cooling fan switch on
automatically and be able to feel air
evacuating from the appliance vents
just below the fascia. The cooling fan
will continue to operate for
approximately 10 minutes after
turning off the burners. This is normal.
If there is no such indication that the
fan is operating, the appliance will
require servicing. DO NOT USE THE
APPLIANCE UNTIL IT HAS BEEN
SERVICED. Switch the appliance off
at the mains and contact Customer
Support.
For your safety
This appliance has a built in safety
device to isolate the gas and electric
supplies to various components in the
event of fan failure.
If the minute minder and lights do not
function, and the ignition system stops
working, the safety device has
operated. Within an hour the safety
device will reset itself and the minute
minder display will flash.
To reset the minute minder, simply
press the reset button and set the time
of day within 5 seconds by pressing
the “+” plus and “-” minus buttons.
If when a burner control is turned on,
the fan does not operate in the normal
way, then the appliance will require
servicing. DO NOT USE THE
APPLIANCE UNTIL IT HAS BEEN
SERVICED. Switch the appliance off
at the mains and contact Customer
Support.
Continued use of the appliance
without it being serviced could result in
excessive temperatures being
generated, which in turn could reduce
the life of certain components.
Ventilation
The use of a gas cooking appliance
results in the production of heat and
moisture in the room in which it is
installed. Ensure that the kitchen is well
ventilated; keep natural ventilation holes
open or install a mechanical ventilation
device (mechanical ventilator).
Prolonged intensive use of the appliance
may call for additional ventilation, for
example opening a window, or more
effective ventilation, for example
increasing the level of mechanical
ventilation where present.
This appliance is not connected to a
combustion products evacuation
device. It must be installed and
connected in accordance with current
installation regulations. Particular
attention must be given to the relevant
regulations regarding ventilation.
3