hussman DBP Ice Maker User Manual


 
IGIP-DBP, DBRP 01,03-0210
10
Maintenance
ELECTRICAL PRECAUTIONS
BEFORE SERVICING – Always disconnect
electrical power at the main disconnect when
servicing or replacing any electrical component
This includes (but not limited to) Fans, Heaters,
Thermostats, and Lights.
REPLACING FLUORESCENT LAMPS
Fluorescent lamps are furnished with a shatterproof pro-
tective coating. The same type of lamp with protective
coating must be used if replaced.
This lamp has been treated to resist breakage and must be
replaced with a similarly treated lamp in order to maintain
compliance with NSF Standards. NSF CODE 4.28.1
Contact HUSSMANN Chino for replacement
1-800-395-9229 x 2131
REPLACEMENT LAMP PART LIST
Refrigerated Lamps
Lamp Q150T3/CL J220/230V150W/79
Our Part No. 125-03-1081 125-03-1141
Voltage 120VAC 220 VAC
Rated Life 1500 Hrs 1500 Hrs
Manufacturer General electric Ushio America, Inc.
Our Cost $7.00 $2.55
Te lephone 1-800-554-4680 1-800-760-7446
1-800-327-0097
General Electric has many national distribution loca-
tions. Call for your closest location.
Ushio America Inc. is located at: 10550 Camden Drive.
Cypress, CA. 90630
T- 5 BULBS
Please note: T-5 lights must be turned off and on after bulb
replacement.
EVAPORATOR FANS
The evaporator fans are located at the center front of
these merchandisers directly beneath the display pans.
Should fans or blades need servicing, always replace fan blades
with the raised embossed side of the blade TOWARD THE
MOTOR.
COPPER COILS
The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
TIPS & TROUBLESHOOTING
Before calling for service, check the following:
1. Check electrical power supply to the equipment for
connection.
2. Check fixture loading. Overstocking case will affect
its proper operation.
3. If frost is collecting on fixture and/or product, check
that Humidity Control is working properly, and that
no outside doors or windows are open—allowing
moisture to enter store.
FOR PROMPT SERVICE
When contacting the factory,
be sure to have the Case Model and Serial
Number handy. This information is on a plate