Electrical and Refrigeration Specifications
TEMPERATURE DISCHG. FAN SIZE DEFROST
ELECTRICAL CIRCUITS
SELF CONTAINED UNIT DATA
BTU AVG AIR T-STAT/ TYPE & FREQ.
115 V.
SELF CONTAINED
REQ’D EVAP PROD DISC VELOC CUT IN OF NUMBER & E E FANS STD. LOW PRESSURE
LENGTH
PER FT. TMP TMP TMP @FPM SETTINGS COIL OF MOTORS DURATION (OPT.) FANS CONTROL & SETTINGS H.P. VOLTS AMPACITY
DBRP-01
Crown 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 1.98 3.6
100 Air (6) (2)
1 point No loads - Connection point only
2 point 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 1.98 3.6
100 Air (6) (3)
3 point 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 2.31 4.2
100 Air (7) (3)
8' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. .66 1.2
100 Air (2) (2)
10' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. .99 1.8
100 Air (3) (2)
12' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 1.32 2.4
100 Air (4) (2)
14' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 1.65 3.0
100 Air (5) (2)
DBRP-01 Octagon
Crown 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 2.64 4.8
100 Air (8) (2)
DBRP-03
8' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. .66 1.2 30# Out 1 208/ 13.0
100 Air (2) (3) 50# In 230
10' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. .99 1.8 30# Out 1 208/ 13.0
100 Air (3) (3) 50# In 230
12' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 1.32 2.4 30# Out 1
1
/2 208/ 19.0
100 Air (4) (3) 50# In 230 -
14' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 1.65 3.0 30# Out 1
1
/2 208/ 19.0
100 Air (5) (3) 50# In 230 -
16' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 1.98 3.6 30# Out 2 208/ 21.4
100 Air (6) (3) 50# In 230 -
18' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 2.31 4.2 30# Out 2 208/ 21.4
100 Air (7) (3) 50# In 230 -
20' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 2.64 4.8 30# Out 3 208/ 35.7
100 Air (8) (3) 50# In 230
22' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 2.97 5.4 30# Out 3 208/ 35.7
100 Air (9) (3) 50# In 230
24' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min.3.3 6.0 30# Out 3 208/ 35.7
100 Air (10) (3) 50# In 230
26' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 3.63 6.6 30# Out 3 208/ 35.7
100 Air (11) (3) 50# In 230
28' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 3.96 7.2
100 Air (12) (3)
30' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 4.29 7.8
100 Air (13) (3)
32' 750 18° 41° 36° 50 to Opt. Forced 8" x 10° 50 min. 5.94 10.8
100 Air (14) (3)
•Hussmann Chino reserves the right to change or revise case specifications and design in connection with any feature of our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions, or replacement of equipment previously sold or shipped. These changes may also affect the loads applicable to a particular case,
therefore always check the serial plate at the back of the case and/or consult the factory for the current loads for your particular equipment.