hussman GSVM Refrigerator User Manual


 
7
each. There are 4 defrost on the 5272 (2
a.m., 8 a.m., 2 p.m., and 8 p.m.) at 30
minutes each
Additional defrost may be re-
quired for cases located in high humidity
or high usage cases. If possible, avoid
setting a defrost during the day, or peak
usage periods. THE CLOCK TIME
POINTER SHOULD BE SET TO THE
CORRECT TIME OF DAY WHEN
THE CABINET IS READY TO BE
STARTED.
Setting the timer
– Extra pins are pro-
vided with the timer.
Put pin in hole of dial face at the time
you wish the cabinet to defrost. Note
that there is an AM and PM section
on the dial face. Be sure the pin is
tight.
Set the length of time for the defrost
(failsafe). Push down on the adjust-
ment and slide it to the length of time.
Do not set the time longer than 60
minutes.
Set the time pointer to the proper
time of day and start cabinet.
CONNECTIONS
-
a. Check cabinet thoroughly for loose
nuts and bolts and electrical connec-
tions.
b. Inspect the refrigeration lines for any
visible damage or chafing.
c. Replace electrical box cover.
d. Replace the louvered access panel.
e. Start the cabinet and allow to pull
down to operating temperature before
loading.