Cornelius 150 8 Valve Beverage Dispenser User Manual


 
4
620904402
c. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon
bristle brush. (Do not use a wire brush). Rinse with clean water.
d. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution.
e. Rinse the B-I-B disconnects in the sanitizing solution.
f. Sanitizing fittings must be attached to each B-I-B disconnect. If these fittings are not available, the
fittings from empty B-I-B bags can be cut from the bags and used. These fittings open the discon-
nect so the sanitizing solution can be drawn through the disconnect.
g. Place all the B-I-B disconnects into the pail of sanitizing solution. Operate all the valves until the
sanitizing solution is flowing from the valve. Allow sanitizer to remain in lines for fifteen
(15) minutes.
h. Remove the nozzle and syrup diffuser from each valve and clean them in a soap solution. Rinse
with clean water and reassemble the nozzle and syrup diffuser to the valve.
i. Remove the sanitizing fittings from the B-I-B disconnects and connect the disconnects to the ap-
propriate B-I-B container. Operate the valves until all sanitizer has been flushed from the system
and syrup is flowing freely.